WITNESS learns how your machines normally run and tells you what deviates, inside your plant.

Hardware and software for condition monitoring: measurement devices on standard PoE record time-series data at your assets, the analytics run in your own server room, and your maintenance staff label the findings. Your data stays yours.

Power fingerprint of one actuator travel Stylised current curve over time: a start-up peak, a constant travel phase and an end-position peak, drawn in red for normal operation. A second, grey curve of a worn drive runs longer and higher and crosses a threshold line, where a red marker flags the deviation. CURRENT TIME THRESHOLD START-UP PEAK CONSTANT TRAVEL END-POSITION PEAK LONGER DEVIATION NORMAL WORN
One travel, one curve: every movement of an actuator leaves a power fingerprint. Stylised, not a measurement.

Trusted in the field

Companies, research institutions and partners already running skAInet Edge-Compute technology.

  • DB Netz AG
  • Framatome
  • Kelvion
  • Kurtz Ersa
  • GSI / FAIR
  • RAG
  • Ruhr-Universität Bochum
  • Montana State University
  • NexuFed AI
TRL 8–9Proven in operation.
40,000+Point machines monitored.
With KelvionIR diagnostics of air-fin coolers evaluated together: 52,440 IR images, 6 coolers, over 12 months.

What WITNESS delivers

WITNESS learns normal behaviour from the time-series data of each asset. The results are written back to your systems and labelled by the people who know the plant best: your maintenance staff.

01

Anomalies

Deviations from normal operation, detected on the time-series data of each asset.

02

Predictions

Estimates of upcoming maintenance needs, such as the remaining life of an actuator.

03

Efficiencies

Estimated efficiencies of the monitored assets, e.g. energy per unit.

How WITNESS works

Modular, on-prem, built on standard PoE. No vendor lock-in.

WITNESS measures the physical condition of your machinery, stores the data in a rack in your own server room and runs the analytics there. Edge computes reach the rack over your normal company Ethernet.

WITNESS architecture Measurement devices in each plant area connect to one edge compute per area. The edge computes reach the skAInet rack in the server room over the company Ethernet, in their own VLAN and TLS-encrypted. The rack holds storage (RAID or Ceph), an inference blade, an API blade and an optional training node. The base API offers REST, MQTT and WebSocket; Docker facades translate it to OPC UA for the DCS, Modbus TCP for the PLC, MQTT Sparkplug B for SCADA and SAP OData or IDoc for the ERP, plus EPICS and InfluxDB. PLANT AREAS SKAINET RACK · SERVER ROOM BASE API DOCKER FACADES YOUR SYSTEMS + EPICS, INFLUXDB COMPANY ETHERNET · OWN VLAN · TLS-ENCRYPTED skAInet PoEpower, temperature skAInet PoEIO-Link, IR camera Third-partyModbus, OPC UA, … Edge computearea A Edge computearea B Edge computearea C Storage RAID or Ceph Inference blade API blade base API Training node optional Base APIREST, MQTT,WebSocket OPC UA server Modbus TCP server MQTT Sparkplug B SAP OData / IDoc DCS PLC SCADA ERP WITNESS architecture Measurement devices in each plant area connect to one edge compute per area. The edge computes reach the skAInet rack in the server room over the company Ethernet, in their own VLAN and TLS-encrypted. The rack holds storage (RAID or Ceph), an inference blade, an API blade and an optional training node. The base API offers REST, MQTT and WebSocket; Docker facades translate it to OPC UA for the DCS, Modbus TCP for the PLC, MQTT Sparkplug B for SCADA and SAP OData or IDoc for the ERP, plus EPICS and InfluxDB. PLANT AREAS SKAINET RACK · SERVER ROOM DOCKER FACADES YOUR SYSTEMS + EPICS, INFLUXDB COMPANY ETHERNET · VLAN · TLS skAInet PoEpower, temperature skAInet PoEIO-Link, IR camera Third-partyModbus, OPC UA, … Edge computearea A Edge computearea B Edge computearea C Storage RAID or Ceph Inference blade API blade base API Training node optional Base APIREST, MQTT, WebSocket OPC UA server Modbus TCP server MQTT Sparkplug B SAP OData / IDoc DCS PLC SCADA ERP

Modular

One or more edge computes per plant area, a rack sized S, M or L, and an optional training node that retrains the models on site with labels from your maintenance staff.

On-prem

No cloud required for storage, inference or training. Devices sit on an isolated LAN behind each edge compute, segmented into their own VLAN, TLS-encrypted; the rack has its own firewall.

Standard PoE

One M12 cable per device carries power and data, which removes many installation hurdles.

No vendor lock-in

Third-party devices with a digital interface connect too. Docker facades for OPC UA, Modbus TCP, MQTT Sparkplug B, SAP OData or IDoc, EPICS and InfluxDB fit WITNESS to what you already run.

Use cases

Every movement of a motor-driven actuator leaves a power fingerprint. WITNESS reads it and tells you the remaining life. For heat exchangers, skAInet IR cameras show fouling as heat.

Rail

Railway points

Every throw of a point machine leaves a power fingerprint. WITNESS reads it and tells you the remaining life.

Condition-based instead of fixed-interval maintenance for point machines with asynchronous motors: an early warning before a throw fails, and replacements you can plan.

Stylised current curve of one throw of a point machine: start-up peak, constant travel and end-position peak. The curve of a worn machine is longer and higher than that of a new one.
One throw, one curve. Stylised, synthetic data.
skAInet PowerProbe for pointsMeasures only the electric and magnetic field: galvanically isolated and non-reactive. Designed to avoid re-approval. Trialled with DB Netze in DIANA.
  • Detects icing, stiffness, contamination, missing lubrication, end-position problems, gearbox wear and bearing damage
  • Remaining life in throws and days, traffic-light status

DB Netze DIANA · 40,000+ point machines monitored

Water

Slide gates

Every travel of a slide gate leaves a power fingerprint. WITNESS reads it and tells you the remaining life.

For sluice and slide gates in water, wastewater and hydraulic engineering: condition-based maintenance, an early warning before a gate gets stuck, and replacements you can plan.

Stylised drift chart: a feature of each travel drifts over time from the green normal zone through an amber zone towards a red anomaly threshold. WITNESS forecasts the remaining life in travels and days.
Drift and forecast. Stylised, synthetic data.
  • Confidence after fewer than 10 travels
  • Confidence that the next travel succeeds
  • Remaining life in travels and days, presented to fit your SCADA or control system

skAInet PowerSense in the control cabinet, PowerProbe as an option

Process industry

Motorised valves

Every stroke of a motorised valve leaves a power fingerprint. WITNESS reads it and tells you the remaining life.

For valve actuators with asynchronous motors: an early warning before a valve fails to open or close, and replacements you can plan for the next shutdown.

Stylised radar chart of six features of one valve stroke: duration, start-up peak current, energy, end-position peak, current profile and power factor. The learned normal range is a band; the current stroke leaves it on duration, energy and end-position peak.
Six features, one shape per stroke. Stylised, synthetic data.
  • Features per stroke: duration, start-up peak current, energy, power factor, current profile, end-position peak
  • Detects stiffness, deposits, missing lubrication, seating problems, gearbox wear

Framatome · in use from the predecessor project

Process plants

Air-fin coolers

Fouling shows up as heat. skAInet IR cameras tell you when to clean.

Continuous infrared diagnostics: fouling that costs cooling capacity is found earlier than on an inspection round, and damaged coolers nobody had noticed are flagged.

Infrared image of an air-fin cooler before cleaning, with bright hot spots on the fouled sections.Before
Infrared image of the same air-fin cooler after cleaning, with a more even surface temperature.After

Same cooler and colour scale, ten days apart. Brighter means warmer: fouled sections stand out as hot spots.

  • Hot-spot map of every cooler and fouling trend over months
  • Cleaning intervals set by condition, no unnecessary cleaning

Evaluated with Kelvion · 52,440 IR images, 6 coolers, 12 months

Hardware

skAInet PoE measurement devices: one cable each for power and data.

Plus any third-party device with a digital interface: USB, Modbus, OPC UA, IO-Link, MQTT, Ethernet; RS-485, CAN and serial via adapters.

Voltage, current, power

PowerSense

Installed in the control cabinet where a direct connection is allowed. Records current, voltage and phase angle at 10 kHz.

Load, non-contact

PowerProbe

Measures only the electric and magnetic field: galvanically isolated and non-reactive, designed to avoid re-approval.

Temperature

TempProbe

36 Type-K thermocouple channels.

Thermal images

IRcam base / premium

Fixed thermal camera, IP67, outdoors all year. Base: 160×120 px, NETD < 50 mK. Premium: 640×512 px, NETD < 35 mK.

IO-Link

iolink

Connects up to 6 IO-Link sensors.

Machine states, signals

IO, StackLight

Reads machine states and signals.

Exploded view of the skAInet PowerProbe: housing, circuit board with Ethernet jack, sensor elements and mounting parts.
PowerProbe, exploded view.
Red skAInet edge compute on a workbench with several M12 PoE cables connected.
Edge compute with M12 PoE cables.
Close-up of the edge compute housing with M12 ports, some of them connected.
Sealed for the shop floor.

Edge compute

One or more per plant area, sealed for the shop floor. Powers and reads the devices, pre-processes the data.

  • 64-bit ARM, 8 GB RAM, 32 GB eMMC
  • 7 M12 PoE LAN ports, 1 Gigabit WAN
  • 48–72 V DC input, IP67
  • −25 to +70 °C operating range
  • Yocto Linux, SBOM, encrypted updates
  • Own mappers in C++ or Python

Details: edge-compute.skainet.io

Network security

Edge computes reach the rack over your normal company Ethernet.

  • Devices on an isolated LAN behind each edge compute
  • Segmented into its own VLAN
  • TLS transport encryption, optional VPN
  • Rack behind its own firewall

For extended cases, federated learning or fully homomorphic encryption are available as options.

The skAInet rack

Storage

RAID or Ceph cluster

All raw data and all results, in your server room. RAID in S, a Ceph cluster in M and L.

Inference blade

Scheduled cron jobs

Anomaly detection, classification, regression, prediction. Writes results back, e.g. bearing damage, imbalance, operating state, remaining useful life, efficiency, energy per unit.

API blade

Base API + facades

REST, WebSocket, MQTT. Docker facades for OPC UA, Modbus TCP, Sparkplug B, SAP OData or IDoc, EPICS and InfluxDB.

Training node

Optional, multi-GPU

Retrains anomaly and prediction models on site with labels from your maintenance staff.

Rack variants. All figures are estimates for sizing talks. Height includes switch and firewall; power is connected load (nameplate), typical draw is lower.
EstimatesSone line or pilotMplant with several areasLlarge site, redundant
Edge computesup to 4up to 12up to 30
Storage1 server, RAID 6, approx. 30 TB usableCeph, 3 nodes, approx. 60 TB usableCeph, 5 nodes, approx. 150 TB usable
Inference, API1 inference blade (CPU), 1 API blade1 inference blade (1 GPU), 1 API blade2 inference blades (GPU), 2 API blades
Training node–optional, 2 GPUsoptional, 4 GPUs
Height incl. networkapprox. 6 Uapprox. 8 U, 12 U with trainingapprox. 12 U, 16 U with training
Connected loadapprox. 1 kWapprox. 1.5 kW, 3 kW with trainingapprox. 3 kW, 5.5 kW with training

Your data.
Your models.

All measurements and results belong to you and stay in your plant. You can deploy your own detections as Docker containers on the inference blade, reading from and writing to the same storage and API as ours. Which models run is up to you.

For industrial insurers

With WITNESS, insurers get clear, physics-based data for the dynamic risk assessment of industrial plants.

Risk surveys, inspections and self-declarations show a plant at one point in time. WITNESS continuously measures the physical condition of critical machinery on site: the risk picture follows the real condition of the plant.

01

Underwriting

Measured, asset-specific condition data instead of self-declarations: a technical basis for the risk assessment.

02

Loss prevention

Detected anomalies and maintenance predictions show where inspections and loss-prevention measures matter most.

03

Claims

A measured history of the physical condition of an asset supports the technical assessment of a loss.

Downloads

One-page summaries of WITNESS as PDF, for your team and your next meeting.

  • OverviewWhat WITNESS is and why it matters
  • Technology platformArchitecture, devices, edge compute, rack variants
  • ArchitectureDevices, edge compute, network, rack, learning loop
  • IntegrationData in, base API, Docker facades to PLC, DCS, SCADA, ERP
  • Use case: railway pointsRemaining life of point machines
  • Use case: slide gatesEarly warning before a gate gets stuck
  • Use case: motorised valvesEarly warning before a valve fails to open or close
  • Use case: air-fin coolersIR cameras find fouling and tell you when to clean
  • For industrial insurersPhysics-based data for dynamic risk assessment

Available on request: hello@skainet.io